mohamed_mourad

د/ محمد زاكى على مراد

Assistant Professor -

Faculty of medicine

Address: قسم الاشعة -كلية الطب

16

Like
Semi-quantitation of pulmonary perfusion heterogeneity on respiratory-gated inspiratory and expiratory perfusion SPECT in patients with pulmonary emphysema.
OBJECTIVE Pulmonary perfusion heterogeneity (PPH) in pulmonary emphysema (PE) was semi-quantified by functional lung volume rate (FLVR) curves obtained from respiratory-gated inspiratory and expiratory single-photon emission computed tomography (SPECT). METHODS::METHODS:: Gated and ungated SPECT were obtained in 36 PE patients [25 with stage IIA and 11 with stage IIB for global initiative for chronic obstructive lung disease (GOLD) stage classification] ... Read more

2006 | Keywords SPECT,
Characterization of 133Xe gas washout in pulmonary emphysema with dynamic 133Xe SPECT functional images.
ABSTRACT PURPOSE: To characterize regional ventilation impairment of pulmonary emphysema using dynamic 133Xe single photon emission computed tomography (SPECT) functional images, compared with other forms of chronic obstructive pulmonary disease (COPD). METHODS: Dynamic 133Xe SPECT was performed in 34 patients with emphysema and 15 patients with other forms of COPD. Three-dimensional voxel-based functional images of the half-clearance time (T1/2) mainly ... Read more

Lymphatic drainage from esophagogastric tract: feasibility of endoscopic CT lymphography for direct visualization of pathways.
PURPOSE: To evaluate the feasibility of an endoscopic computed tomographic (CT) lymphography technique with submucosal injection of iopamidol for direct visualization of lymphatic drainage pathways in dogs and in patients with operable esophageal cancer. MATERIALS AND METHODS: With institutional animal committee approval, a total of 2 mL of undiluted iopamidol was injected into the esophageal (n = 6) or gastric ... Read more

2005 | Keywords Pulmonary thromboembolism,
Preferential location of acute pulmonary thromboembolism induced consolidative opacities: assessment with respiratory gated perfusion SPECT-CT fusion images.
PURPOSE: Preferential location of acute pulmonary thromboembolism (PTE) induced consolidative opacities (infarction/atelectasis) was determined on respiratory gated perfusion SPECT-CT fusion images. METHOD: Gated end-inspiratory perfusion SPECT images were obtained in 21 patients with acute PTE and 17 patients with inflammatory diseases, using a triple-headed SPECT system and a respiratory tracking device. Anatomical relationships of consolidative opacities and perfusion defects were ... Read more

2005 | Keywords pulmonary malignant tumours,
Initial application of respiratory-gated 201Tl SPECT in pulmonary malignant tumours.
AIM: Respiratory-gated thallium-201 chloride (201Tl) single photon emission computed tomography (SPECT) was used in preliminary investigations to reduce the adverse respiratory motion effects observed on standard ungated SPECT images and to obtain reliable fusion images with computed tomography (CT) in patients with malignant lung tumours. METHODS: Fifteen patients with primary lung cancer (n=10) or metastatic lung tumours (n=5) underwent gated ... Read more

Assessment of lung perfusion impairment in patients with pulmonary artery-occlusive and chronic obstructive pulmonary diseases with
PURPOSE: To evaluate the ability of noncontrast electrocardiogram (ECG)-gated fast-spin-echo (FSE) perfusion MR images for defining regional lung perfusion impairment, as compared with technetium (Tc)-99m macroaggregated albumin (MAA) single-photon emission computed tomography (SPECT) images. MATERIALS AND METHODS: After acquisition of ECG-gated multiphase FSE MR images during cardiac cycles at selected lung levels in nine healthy volunteers, 11 patients with pulmonary ... Read more

2004 | Keywords lung function impairment,
Assessment of regional lung function impairment in airway obstruction and pulmonary embolic dogs with combined noncontrast electrocardiogram-gated perfusion and gadolinium .........
PURPOSE: To define regional function impairment in airway obstruction (AO) and pulmonary embolic (PE) dogs with a combination study of noncontrast electrocardiogram (ECG)-gated perfusion and gadolinium diethylenetriaminepentaacetic acid (Gd-DTPA) aerosol magnetic resonance (MR) images. METHODS: After acquisition of multiphase fast-spin-echo (FSE) MR images during cardiac cycles in 14 AO dogs and 19 PE dogs, ECG-gated perfusion-weighted (PW) images were obtained ... Read more

2004 | Keywords lung cancer,
Clinical utility of co-registered respiratory-gated( 99m)Tc-Technegas/MAA SPECT-CT images in the assessment of regional lung functional impairment in patients with lung cancer.
PURPOSE: The aim of the study was to provide preliminary validation of the utility of co-registered respiratory-gated ventilation/perfusion single-photon emission computed tomography-computed tomography (SPECT-CT) images in the assessment of regional lung functional impairment in patients with lung cancer. METHODS: Twenty untreated and three radiotherapy-treated patients with lung cancer underwent gated( 99m)Tc-Technegas/macroaggregated albumin (MAA) SPECT, using a triple-headed SPECT unit and ... Read more

2004 | Keywords Sentinel lymph node,
Computed tomography lymphography with intrapulmonary injection of iopamidol for sentinel lymph node localization.
PURPOSE: Experimental and clinical evaluation of the potential utility of indirect computed tomographic lymphography (CT-LG) with intrapulmonary injection of iopamidol for preoperative localization of sentinel lymph node station in non-small cell lung cancer. METHODS: CT-LG with intrapulmonary injection of 0.5 mL of undiluted iopamidol was performed in 10 dogs using a multidetector-row CT unit, followed by postmortem examination of enhanced ... Read more

2004 | Keywords pulmonary perfusion,
Pulmonary perfusion assessment with respiratory gated 99mTc macroaggregated albumin SPECT: preliminary results.
PURPOSE: Respiratory gated perfusion single photon emission computed tomography (SPECT) was applied to reduce respiratory lung motion effects and to reliably assess perfusion impairment in various lung diseases. METHODS: After injection of 259 MBq of 99mTc macroaggretated albumin (99mTc-MAA), gating was performed using a triple-headed SPECT unit connected to a physiological synchronizer in a total of 35 patients with either ... Read more